Aerospace
Aerospace Component Precision Cleaning Water
Pure water plant supplying precision cleaning and passivation lines for aerospace parts.
Challenge
Project Requirements
Precision machined and surface-treated aerospace components cannot tolerate ionic residue or particles after rinsing, and the plant needed guaranteed availability during production shifts.
Engineered Solution
- Duplex pre-treatment trains allowing maintenance without shutdown
- Double-stage reverse osmosis with automatic flush and CIP circuit
- Mixed-bed polishing for final ionic removal
- Buffer tank plus circulating loop with UV sterilisation
Results
Outcome On Site
Rinse water conductivity held below 1 μS/cm
No production stoppage during routine maintenance
Reduced part rejection caused by drying spots and residue
Site Photos
Installation Gallery